Miele HR 1421 Installation Instructions Manual page 33

30" electric, 30" induction range 30", 36" all gas range 30", 36", 48" dual fuel range
Table of Contents

Advertisement

HR 1124
Position
Dimensions
Min. 30"
(762 mm)
6" +  + 6"
(150 mm +  +
150 mm)
37" (940 mm)
30" (762 mm)
For all other Hoods please consult the manufacturer's specifications
for required distances.
Approx.
10 13/16" (274 m
Approx.
4 1/2" (115 mm)
Approx.
2 13/16" (72 mm)
From the back side of the cooktop, a 12" (305 mm) minimum distance to the combustible
rear wall above the countertop is required.
Description
Width of cabinet opening
If combustible materials are present, an additional
minimum distance of 6" (150 mm) (each side) is
required. Ensure that local codes are observed.
Minimum distance between the top of the cooking
area and the bottom of an unprotected
combustible surface.
Minimum distance between the top of the cooking
area and the bottom of the Miele Range Hood
(DAR model with DRxB XL blower).
Maximum connection width right
and left
m)
Maximum connection height
Maximum connection depth
All Gas Range dimensions
Position of
the wall
socket
33

Hide quick links: