To remove the aluminium grease filters for cleaning
While supporting the weight of the lower half of the globe, use the
special tool supplied with the appliance to unscrew the metal ring
that secures it (Fig. 2).
Place the lower half of the globe, chrome lower cover and locking
ring aside safely.
Slacken one of the retaining screws ("A" in Fig. 3) by a maximum of
one turn.
Swing the retaining tab ("B" in Fig. 3) aside to release the carbon
filter and aluminium grease filter.
Pull the carbon filter and aluminium grease filter downward from
their housing.
Repeat this to remove the second set of carbon filter and aluminium
grease filter.
To re-fit the aluminium grease filters after cleaning
Slide one carbon filter and one aluminium grease filter back into
the housing on one side of the motor, ensuring that the aluminium
grease filter is located furthest from the motor itself.
Swing the retaining tab ("B" in Fig. 3) into position to hold the filters
in place.
Tighten the retaining screw ("A" in Fig. 3) to secure the retaining tab
in position.
Fit the other carbon filter and aluminium grease filter in a similar way.
Relocate the lower half of the globe and chrome lower cover to the
extractor body, then secure them using the locking ring, removed
earlier. Tighten this hand-tight using the special tool supplied with
the appliance.