If a dc or ac voltage greater than about 3 V is present across the inputs
when the meter is set to k CHEK, the meter switches automatically to dc
or ac voltage mode and displays the voltage.
When k CHEK is activated, the meter has low input impedance (LoZ)
≅3 kΩ. This load can alter the voltages in electronic control circuits. Do
not use k CHEK to measure voltage in circuits that could be damaged by
a 3 kΩ load.
CHEK can be effectively used to eliminate "ghost"
k
voltages.

AC and DC Voltage

Also refer to k Chek.
Volts
Input Impedance ≅3 kΩ
Note
AC for AC Voltage
DC for DC Voltage
6 V
RANGE
60 V
600 V
fda02.eps