Excalibur AL-1670-B Operation Manual page 21

Remote start & security
Table of Contents

Advertisement

Feature #10 - Turbo Timer
Off
(press LOCK to program)
Run 1 Minute
(press UNLOCK to program)
Run 2 Minutes (press TRUNK to program)
Run 3 Minutes (press START to program)
This feature, the operation of which is described on page 8, when turned on
configures the system to automatically keep the engine running briefly after the key is
turned off. This operation is designed specifically for vehicles with turbocharged engines.
NOTE: This feature is dependent on the proper wiring of the neutral safety circuit.
Feature #11 - Manual Transmission Reservation Mode
On
(press LOCK to program)
Off
(press UNLOCK to program)
This feature changes the parameters of the system's remote start operation to be suitable
for manual transmission-equipped vehicles via a "setup" procedure which must be fol-
lowed upon exiting the vehicle to ensure the transmission is in neutral�
Feature #12 Data Port Protocol
Green: DBI, Black: DBI
Green: iData, Black: iData
Green: DBI, Black: iData
Green: iData, Black: DBI
This feature determines which data protocol is used on each data port� Choose this based
on the accessory being connected to the port� NOTE: When a BLADE is inserted, this
feature automatically switches the black port to the iDatalink protocol.
Feature #13 - Alarm Functions
On
Off
Off- Unlock Only
Sensor Detect
This feature converts keyless entry models to full alarm systems (installation changes may
be required)� Sensor Detect automatically turns on alarm functions when a sensor is con-
nected to the sensor port or data port�
Feature #14 - Pulse Ignition On Disarm
On
(press LOCK to program)
Off
(press UNLOCK to program)
This feature will pulse the ignition and activate any attached immobilizer bypass module
for vehicles that require the ignition to be turned on to disarm the OEM alarm�
Feature #15 Lock On Prewarn
On (press LOCK to program)
Off (press UNLOCK to program)
This feature will automatically lock the doors to combat unauthorized entry from lock pick-
ing when the prewarn zone is triggered�
Feature #16 - Starter Interrupt Functions
Alarm Only
Anti-Grind Only
Alarm & Anti-Grind
Automatic
Alarm Only - The Starter Interrupt is operable whenever the alarm is armed�
Anti-Grind Only - The Starter Interrupt is operable whenever remote start is on�
Alarm & Anti-Grind - This setting engages starter interrupt when the alarm is armed AND
when the system is in remote start mode�
Automatic - The Starter Interrupt output will automatically engage 90 seconds
after the ignition switch is turned "off", and after disarming the system�
Installer Programmable Features (cont'd)
(press LOCK to program)
(press UNLOCK to program)
(press TRUNK to program)
(press START to program)
(press LOCK to program)
(press UNLOCK to program)
(press TRUNK to program)
(press START to program)
(press LOCK to program)
(press UNLOCK to program)
(press TRUNK to program)
(press START to program)
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rs-370Rs-375-3dRs-375-3db

Table of Contents