Appendix D Specifications - HP ProDesk 400 G2 Small Form Factor Maintenance And Service Manual

Table of Contents

Advertisement

D
Specifications
Chassis (in the desktop position)
Height
Width
Depth
Approximate Weight
Weight Supported (maximum distributed load in desktop position)
Temperature Range
Operating
Nonoperating
NOTE:
Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct sustained
sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and number of options installed.
Relative Humidity (noncondensing)
Operating
Nonoperating (38.7°C max wet bulb)
Maximum Altitude (unpressurized)
Operating
Nonoperating
Power Supply
Operating Voltage Range
Rated Voltage Range
Rated Line Frequency
Operating Line Frequency
Standard Efficiency
High Efficiency
Rated Input Current
This system utilizes an active power factor corrected power supply. This allows the system to pass the CE mark requirements for use
1
in the countries of the European Union. The active power factor corrected power supply also has the added benefit of not requiring
an input voltage range select switch.
1
3.93 in
100 mm
13.26 in
33.7 cm
14.98 in
380 mm
13.0 lb
5.9 kg
77 lb
35 kg
50° to 95°F
10° to 35°C
-22° to 140°F
-30° to 60°C
10-90%
10-90%
5-95%
5-95%
10,000 ft
3048 m
30,000 ft
9144 m
90-264 VAC
100-240 VAC
50-60 Hz
47-63 Hz
240W active PFC
240W active PFC
82/85/82% efficient at 20/50/100% load (230V)
4A
137