Control panel message
2219-USB Key Provisioning file has invalid
header identifier
2220-USB Key Provisioning file has mismatch
version
2230-General error during MEBx execution
2231-ME error during MEBx execution
2232-AMT error during MEBx execution
2233-HECI error during MEBx execution
2239-ME image lock failure
2240-ME image unlock failure
Description
Provisioning file contained on the USB key has
been corrupted or is not a valid version for the
current ME firmware.
Provisioning file contained on the USB key is
not a valid version for the current ME firmware.
Error occurred during MEBx execution which
fails into the "General" grouping. Status
information displayed along with the error
provides further clarity into the failure. MEBx
handles transference of information between
the system BIOS and ME firmware.
Error occurred during MEBx execution which
fails into "ME" grouping.
Error occurred during MEBx execution which
fails into "AMT" grouping.
Error occurred during MEBx execution which
fails into "MEI or HECI" grouping.
Special system configurations with reduced ME
firmware image require BIOS control of ME
firmware upgrading. A failure has occurred
after the ME firmware update process in which
the BIOS could not relock the ME firmware
region.
Special system configurations with reduced ME
firmware image require BIOS control of ME
firmware upgrading. A failure has occurred
prior to the ME firmware update process in
which the BIOS could not unlock the ME
firmware region.
Recommended action
1.
Recreate the provisioning file using third
party management console software.
2.
If the error persists and system BIOS has
been recently updated, restore previous
system BIOS version. Otherwise, update
the ME firmware version.
3.
If the error still persists, replace the
system board.
1.
Reboot the computer.
2.
If the error persists and system BIOS has
been recently updated, restore previous
system BIOS version. Otherwise, update
the ME firmware version.
3.
If the error still persists, replace the
system board.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version and ME firmware version.
3.
If the error still persists, replace the
system board.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version and ME firmware version.
3.
If the error still persists, replace the
system board.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version and ME firmware version.
3.
If the error still persists, replace the
system board.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version and ME firmware version.
3.
If the error still persists, replace the
system board.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version and ME firmware version.
3.
If the error still persists, replace the
system board.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version and ME firmware version.
3.
If the error still persists, replace the
system board.