HP ProDesk 400 G2 Small Form Factor Maintenance And Service Manual page 118

Table of Contents

Advertisement

Control panel message
2203-Setup error during MEBx execution
2204-Inventory error during MEBx execution
2205-Interface error during MEBx execution
2211-Memory not configured correctly for
proper MEBx execution.
2212-USB Key Provisioning failure writing to
device
2217-ME Firmware Version request failure
2218-ME Firmware Version should be updated
110 Chapter 7 POST error messages
Description
MEBx selection or exit resulted in a setup
failure.
BIOS information passed to the MEBx resulted
in a failure.
MEBx operation experienced a hardware error
during communication with ME.
DIMM1 or XMM1 is not installed.
USB device used for USB key provisioning will
not allow BIOS to update provision file
properly.
ME firmware is not properly responding to BIOS
query for version information.
ME firmware must be updated to match current
functionality contained in the system BIOS.
Recommended action
3.
If the memory configuration was recently
changed, unplug the power cord, restore
the original memory configuration, and
reboot the computer.
4.
If the error persists, replace the system
board.
1.
Reboot the computer.
2.
Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3.
If the memory configuration was recently
changed, unplug the power cord, restore
the original memory configuration, and
reboot the computer.
4.
If the error persists, replace the system
board.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version.
3.
If the error still persists, replace the
system board.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version.
3.
If the error still persists, replace the
system board.
Make sure there is a memory module in the
black DIMM1 socket and that it is properly
seated.
1.
Try a different USB key device for
provisioning.
2.
If the error persists, update to the latest
BIOS version and ME firmware version.
3.
If the error still persists, replace the
system board.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version and ME firmware version.
3.
If the error still persists, replace the
system board.
1.
Update to the latest ME firmware version.
2.
If the error persists and system BIOS has
been recently updated, restore previous
system BIOS version.
3.
If the error still persists, replace the
system board.

Hide quick links: