2) Communication in ASCII code
(Data name)
External device
*
side
(Example)
H L
0
1
F
F
30
31
46
46
H
H
H
(Data name)
PLC side
(Example)
Head device
H
-
-
L
H
-
-
-
-
-
-
0
0 0 A 5
9
2
0
0
0
0
30
30
30
41
35
39
32
30
30
30
30
H
H
H
H
H
H
H
H
H
H
H
H
Y100
Y100 (Octadecimal) = 40 (Hexadecimal)
"8"
1 0 0 0 0 0 1 0 1 0 0 1 1 1 0 1 0 1 0 1 0 1 0 1 0 0 1 1 1 1 1 0
Y117
to
-
-
-
-
L
H
L
0
0
0
4
0
0
2
0
0
30
30
30
34
30
30
32
30
30
H
H
H
H
H
H
H
H
H
32/16 = 2 points
*
"2"
"9"
"D"
Y110
Y107
to
Y100
Y137
7 Communication Using MC Protocol