7.7.5
Terminal input read
Analog input value of terminal 2, 4, 1 can be read.
PNU
P5.1
Terminal 2 input value read
P5.2
Terminal 4 input value read
P5.3
Terminal 1 input value read
7.7.6
Inverter reset
The inverter can be reset from the master.
PNU
P6
Inverter reset
⋅
The inverter maintains the resetting status while reset is requested.
≠ "0, 2, 14, 16", reset is enabled only during an inverter error.
⋅
When Pr.75
7.7.7
Node address read
The node address of the inverter can be read.
PNU
P918
Node address read
Item
Terminal 2 input value (%) is read.
Terminal 4 input value (%) is read.
Terminal 1 input value (%) is read.
Item
The inverter is reset after the data was written
from the master.
Item
Set node address is read.
PPO TYPE SUPPORT
Data Definition
Data Definition
Data Definition
SPECIFICATION
Data Type
AUs16
AUs16
AUs16
Data Type
Us16
Data Type
Us16
7
55