Mitsubishi Electric FR-A7NP Instruction Manual page 82

Profibus-dp communication function
Hide thumbs Also See for FR-A7NP:
Table of Contents

Advertisement

PPO TYPE NON SUPPORT
SPECIFICATION
(2) Inverter status/operation command
The inverter status can be monitored and operation command can be given from the master.
IND
PNU
Inverter status
Refer to page 70 for details.
Run command
Name
Terminal STF
Terminal STR
Terminal RH
0100
A
H
H
Terminal RM
Terminal RL
Terminal JOG
Terminal RT
Terminal AU
Terminal CS
Terminal MRS
76
Bit
0
Reserved (0 is set)
1
Forward rotation command
2
Reverse rotation command
3
High-speed operation command
4
Middle-speed operation command
5
Low-speed operation command
6
JOG operation selection
7
Second function selection
8
Terminal 4 input selection
Restart after instantaneopus power
9
failure selection
10
Inverter output shut off
11 to 15 Not used (0 is set)
Item
Definition
Functions assigned to terminal
*
RH, RM, RL, JOG, RT, AU, CS
*
and MRS are activated.
*
*Signal names are initial values.
Using Pr. 180 to Pr .187, you can
*
change output signal functions.
*
Refer to the inverter manual
*
(applied) for details of Pr. 180 to
Pr.187.
*
*

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents