PPO TYPE SUPPORT
SPECIFICATION

7.5 Buffer Memory Details

The following indicates the buffer memory details of the Profibus profiles.
Name
PNU
SPM
PKE
AK
PKW
IND
44
Bit
0 to 10 PNU number
11
Not used (0 is set)
[Command request]
0
: No task
1
: Parameter value is requested (read request)
2
: Parameter value (word) is changed (write request)
3 to 5 : Non-supported
6
: Parameter value (array) is requested (read request)
7
: Parameter value (array word) is changed (write request)
8 to 15 : Non-supported
12 to 15
[Command response]
0
: No response (Busy status)
1
: Parameter value (word) is transferred.
2 to 3 : Non-supported
4
: Parameter value (array word) is transferred.
5 to 6 : Non-supported
7
: Command execution error (error number is stored into PWE)
8 to 15 : Non-supported
0 to 7
Reserved area for extension (0 is set)
Sub-Index number
8 to 15
At command request, set this number when AK =6, 7.
Definition