(3) Operation mode write
Write of the operation mode can be performed from the master.
IND
PNU
0100
B
H
H
(4) Set frequency read/write
The frequency set to the inverter can be read/written from the master.
IND
PNU
0100
D
H
H
0100
E
H
H
*1
Writing to PNU = D
H
*2
To change the running frequency consecutively, always write data to the inverter RAM.
(5) Terminal input read
The analog input values of terminal 2, 4, 1 can be read.
IND
PNU
0100
1
Terminal 2 input value read
H
H
0100
2
Terminal 4 input value read
H
H
0100
3
Terminal 1 input value read
H
H
Item
Operation mode
Item
Set frequency (RAM)
*1
Set frequency (EEPROM)
or PNU = E
can be read out from PNU = D
H
Name
External operation mode:10
PU operation mode:11
Network operation mode:14
Set frequency (RAM) is read or written.
Write set frequency to EEPROM.
*1,2
.
H
Minimum
Setting
Increments
0.1%
0.1%
0.1%
PPO TYPE NON SUPPORT
SPECIFICATION
Data Definition
H
When Pr.79
(
= "6")
H
H
Data Definition
8
77