Operation; Monitoring Refill Operation - Nordson ProBlue Fulfill Customer Product Manual

Integrated fill system
Hide thumbs Also See for ProBlue Fulfill:
Table of Contents

Advertisement

ProBlue Fulfill Integrated Fill System
20

Operation

Monitoring Refill Operation

Part 1101094_02
Once enabled, the fill system immediately begins operation. All that is
required to maintain automatic refill operation is to maintain the level of
adhesive in the adhesive storage bin.
Under normal conditions, there is no need for the operator to monitor or
intervene in the operation of the fill system. However, if the fill system is
unable to satisfy the level sensor in the time limit set for the Fill Time Delay
(parameter 48), the claxon alarm will sound, the refill alarm LED will
illuminate, and the melter display will indicate F9.
Refer to the next procedure, Clearing a Refill Alarm, to clear a refill alarm.
Refer to Troubleshooting for information about diagnosing and correcting
potential fill system problems.
NOTE: A refill alarm (F9) is a warning. The melter will not shut down when
this alarm occurs. This alarm occurs when the fill system has tried to fill the
melter for the amount of time specified in parameter 47 (Fill Time Delay) but
has not satisfied the level sensor.
NOTE: If the lid is open, the fill system will not operate. An open lid condition
is indicated by a flashing fill system enable key LED.
NOTE: If the air supply is shut off by the parent machine, a fault condition
will occur.