Optical Card Performance Monitoring; Oc-48/Stm16 And Oc-192/Stm64 Card Performance Monitoring Parameters - Cisco ONS 15600 Series Reference Manual

Multiservice switching platform (mssp)
Hide thumbs Also See for ONS 15600 Series:
Table of Contents

Advertisement

Chapter 12
Performance Monitoring
Table 12-2
Parameter
UAS-L
UAS-LFE
UAS-P
UAS-PFE

12.5 Optical Card Performance Monitoring

The following sections define performance monitoring parameters for the OC-48/STM16 and
OC-192/STM64 optical cards.
12.5.1 OC-48/STM16 and OC-192/STM64 Card Performance Monitoring
Parameters
Figure 12-4
Circuits (ASICs) produce performance monitoring parameters for the OC-48/STM16 and
OC-192/STM64 optical cards.
Performance Monitoring Parameters (continued)
Definition
Line Unavailable Seconds (UAS-L) is a count of the seconds when the line is
unavailable. A line becomes unavailable when ten consecutive seconds occur that
qualify as SES-Ls, and it continues to be unavailable until ten consecutive seconds
occur that do not qualify as SES-Ls.
Far-End Line Unavailable Seconds (UAS-LFE) is a count of the seconds when the
line is unavailable at the far end. A line becomes unavailable at the onset of ten
consecutive seconds that qualify as SES-LFEs, and continues to be unavailable until
the onset of ten consecutive seconds occurs that do not qualify as SES-LFEs.
Near-End STS Path Unavailable Seconds (UAS-P) is a count of the seconds when the
STS path was unavailable. An STS path becomes unavailable when ten consecutive
seconds occur that qualify as SES-Ps, and continues to be unavailable until ten
consecutive seconds occur that do not qualify as SES-Ps.
Far-End STS Path Unavailable Seconds (UAS-PFE) is a count of the seconds when
the STS path was unavailable. An STS path becomes unavailable when ten
consecutive seconds occur that qualify as SES-PFEs, and continues to be unavailable
until ten consecutive seconds occur that do not qualify as SES-PFEs.
shows where overhead bytes detected on the Application-Specific Integrated
12.5 Optical Card Performance Monitoring
Cisco ONS 15600 Reference Manual, R7.0
12-9