3.1

Electrical

Specifications are given for an ambient temperature of 23°C ± 3°C, rela-
tive humidity of 45 to 55%, supply voltage of 6V ± 0.2V and magnetic field
of <40A/m.
INPUT VOLTAGE CHECK
Measurement Range
Resolution
Input Impedance
Frequency Range
RESISTANCE
Measurement
Range
Resolution
Accuracy
Measurement
current
Open voltage
(1) With nominal value of 10.2A, the measurement current is at least 10A whatever the charge condition of the battery.
(2) The current is 10mA only up to 300Ω. If the battery is low, it can fall to as low as 8mA.
VOLTAGE MEASUREMENT INDICATION
Measurement
Range
Resolution
CURRENT MEASUREMENT INDICATION
Measurement
Range
Resolution
Micro-Ohmmeter Model 6240

SPECIFICATIONS

10.0 to 39.99V
0.01V
5.0 to
4.0 to
3999µΩ
39.99mΩ
1µΩ
10µΩ
10.2A
± 2%
(1)
0.01 to
4.0 to
3.999mV
39.99mV
1µV
10µV
5.0 to
39.99mA
10µA
CHAPTER 3
40.0 to 399.99V
800kΩ
DC and 15.3 to 450Hz
40.0 to
399.9mΩ
100µΩ
± 0.25% ± 2ct
1.02A
± 2%
4 to 6V
40.0 to
399.9mV
100µV
40.0 to
399.9mA
100µA
0.1V
400 to
4.0 to
3999mΩ
39.99Ω
1mΩ
10mΩ
102mA
± 2%
0.40 to
3.999V
1mV
0.40 to
3.999A
1mA
400 to 499V
1V
40.0 to
399.9Ω
100mΩ
10.2mA
± 2%
(2)
4.0 to
4.70V
10mV
4.0 to
11.00A
10mA
11

Hide quick links: