Register Name
AZT Correction
Auto Zero Max Dev
Total AZ %
AZT step limit
Belt Warm
High Rate Set
Low Rate Set
High Speed Set
Low Speed Set
High Load Set
Low Load Set
Cal Error
Master Total Double
Reset Total Double
Operator Total Double
Batch Total Double
Thermo Fisher Scientific
downloaded by the user (if in Manual mode) or calculated by the integrator.
Defines when the Load Out has to stop to compensate the queue of material from
the loading point to the scale.
The AZT function accurately tracks the zero of the scale, by calculating an
additional zero constant. The portion of zero due to AZT is not incorporated in the
zero constant, but is shown separately.
The current value of auto zero maximum deviation.
The current value of total auto-zero %.
The current value of auto zero-tracking step.
The current value of belt warm-up time.
The set point for the alarm of high rate in percent of the Scale Capacity value.
Entered or downloaded by the user.
The set point for the alarm of low rate in percent of the Scale Capacity value.
Entered or downloaded by the user.
The set point for the alarm of high speed in percent of the Belt Speed Capacity
value. Entered or downloaded by the user.
The set point for the alarm of low speed in percent of the Belt Speed Capacity
value. Entered or downloaded by the user.
The set point for the alarm of high belt loading in percent of the Belt Load Capacity
value. Entered or downloaded by the user.
The set point for the alarm of low belt loading in percent of the Belt Load Capacity
value. Entered or downloaded by the user.
Indicates in percent, the zero or span error computed at the end of a remote
calibration function.
The master can evaluate it before accepting the result of a remote "autozero" or
"autospan".
The current value of the master totalizer of the Micro-Tech. (In double precision
float format.)
The current value of the reset totalizer of the integrator. (In double precision float
format.)
The current value of the operator totalizer of the integrator. (In double precision
float format.)
Display Table
Display
Hex
Display ( 1 )
2DH
display ( 2 )
4DH
display ( 3 )
4EH
display ( 4 )
20H
display ( 5 )
41H
display ( 6 )
4EH
display ( 10 )
Description
Hex
Description
20H
Characters 1 and 2 from left of first row
45H
55H
4DH
49H
20H
characters 19 and 20 from left of first row
Micro-Tech 9101/9201 Reference Manual, Rev J
C-11