4. When using the chain calibration procedure, after applying the chain,
the following screen appears.
READY
BATCH
ALARM
AUTO SPAN Chain
Run belt, the
Press START
START
EXIT
After starting the belt, make sure the chain placement is proper
before proceeding by pressing the Start button.
5. Using R-Cal, Chain, or Weights, after the Span Calibration has been
executed the following screen will display if a material calibration
has been done before and the current simulated load method has no
material factor installed.
READY
BATCH
ALARM
AUTO SPAN COMPLETE
Error
Unfactored Calcon
EXIT
FACTORS
REPEAT
Ignore this screen and press Exit. Automatic Material Factoring
should not be used. If you want to use the manual Material
Factoring procedure, see page A-12.
6. Using Chains or Weights, if the Error is below the critical threshold
of 0.50% (0.25% for Model 9201 integrator) press No when the
integrator asks if the span should be changed. If the Error is greater
than 0.50% there may be a problem. Press No and see the
troubleshooting section for additional help.
CALIB
CALIB
X.XX%