Download Print this page

Thermo Scientific Micro-Tech 9101 Reference Manual page 167

Belt conveyor scale integrator

Advertisement

Thermo Fisher Scientific
"Channel 2," bottom connector has jumpers J19 and J20 that allow
selection of either external excitation sense (6-wire LC hook-up) or
internal excitation sense (4-wire LC hook-up).
One of four different interrupt channels can be selected from J1 jumper.
J1 is board interrupt 1-2 this is a factory installed jumper, do not move.
Load-Cell Sense Jumper Defaults
Four-Wire Load-Cell
Jumper
(internal sense)
J14
J15
J19
J20
Factory option jumpers W2 and W3 allow the A/D converters to operate
at either 10 conversions per second or at 80 conversions per second,
which may be useful for "loss-in-weight" applications. The standard
board is hard-wired for 10 conversions per second. Altering the W2/W3
option jumpers allows software selection of the desired conversion rate,
so do not change.
Jumper Locations
Six-Wire Load-Cell
(external sense)
1-2
1-2
1-2
1-2
Micro-Tech 9101/9201 Reference Manual, Rev J
2-3
2-3
2-3
2-3
A-45

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Micro-tech 9201