Download Print this page

Thermo Scientific Micro-Tech 9101 Reference Manual page 219

Belt conveyor scale integrator

Advertisement

No.
Parameter
8
Remote counter
pulse div.
9
Remote counter
pulse width
10
Type board 1
8in8out
11
Type board 2
8in8out
12
Clip detect mode
13
Clip detect length
Thermo Fisher Scientific
Selection
1
Low load
2
High rate
2
Low rate
3
High speed
3
Low speed
Totalizer
4
Print ready
Load WTS
4
Dev. Alarms
4
Out of range
Zero Ready
Fault
5
Batch
1 ton (0.01 - 100)
0.100 sec (0.005 - 1)
Source, Sink
Source, Sink
Manual, Auto
1.0 ft (0.5-10)
Description
1
0 NO
Only available if load alarm is
defined in ALARMS DEFINE
scroll.
0 NO
2
Only available if rate alarm is
0 NO
defined in ALARMS DEFINE
scroll.
0 NO
3
Only available if speed alarm is
defined in ALARMS DEFINE
0 NO
scroll.
4
Only available when NTEP is
0 NO
selected for W&M mode.
0 NO
5
Only available if Loadout card
installed.
0 NO
0 NC
0 NO
0 NO
4 NC
0 NO
Note: Only present when
Totalizer output is defined.
Note: Only present when
Totalizer output is defined.
Micro-Tech 9101/9201 Reference Manual, Rev J
B-47

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Micro-tech 9201