Belt conveyor scale integrator

Advertisement

No.
Parameter
3B
High speed set
Alarm Number
Alarm
Number
#1
#3
#4
#7
#8
#10
#13
#16
#19
#22
#25
B-50
Micro-Tech 9101/9201 Reference Manual, Rev J
___ ___
Description
Clock Fail
Signal cell fail S1
Signal cell fail S2
RAM fail
ROM fail
High load
Low load
High rate
Low rate
High speed
Low speed
Selection
100% (0 - 150%)
10 sec (0 - 90 sec)
600 FPM (0 - 900 FPM)
Selection
ALARM, SHUT DOWN, AUTO
RES., NONE
ALARM, SHUT DOWN, AUTO
RES., NONE
ALARM, SHUT DOWN, AUTO
RES., NONE
ALARM, SHUT DOWN, AUTO
RES., NONE
ALARM, SHUT DOWN, AUTO
RES., NONE
ALARM, SHUT DOWN, AUTO
RES., NONE
ALARM, SHUT DOWN, AUTO
RES., NONE
ALARM, SHUT DOWN, AUTO
RES., NONE
ALARM, SHUT DOWN, AUTO
RES., NONE
ALARM, SHUT DOWN, AUTO
RES., NONE
ALARM, SHUT DOWN, AUTO
RES., NONE
Description
Description
The system has detected a
failure on the clock calendar
circuit. Go to the Diagnostics
menu and re-enter the date
and time. Check the battery.
Replace the motherboard.
The system has detected an
error on the RAM (Random
Access Memory) checksum
during the internal periodic
test. The RAM is used to
store variables and set up
data.
Replace the motherboard.
The system has detected an
error on the ROM (Read Only
Memory) checksum during
the internal periodic test. The
ROM is used to store the
program.
Replace the motherboard.
Only present when Load
alarm is set to Yes.
Only present when Load
alarm is set to Yes.
Only present when Rate
alarm is set to Yes.
Only present when Rate
alarm is set to Yes.
Only present when Speed
alarm is set to Yes.
Only present when Speed
alarm is set to Yes.
Thermo Fisher Scientific