HAZARDOUS LOCATIONS
CERTIFICATIONS
Factory Mutual (FM) Approvals
E5
Explosion-proof for
Class I, Division 1, Groups B, C, and D;
Dust-Ignition proof for
Class II/III, Division 1, Groups E, F, and G;
factory sealed
I5
Intrinsically safe for use in
Class I, Division 1, Groups A, B, C, and D;
Class II/III, Division 1, Groups E, F, and G;
Temp. code T4 only when connected in accordance with
Rosemount drawings 08800-0106 and 00268-0031;
Non-incendive for
Class I, Division 2, Groups A, B, C, and D;
factory sealed.
Entity Parameters:
U
= 30 V
i
I
= 300 mA
i
P
= 1.3 W
i
C
= 0.0
F
m
i
L
= 40
H
m
i
K5
E5 and I5 combination
U
= 30 V
i
I
= 300 mA
i
P
= 1.3 W
i
C
= 0.0
F
m
i
L
= 40
H
m
i
Reference Data
A-13