IBM Storwize V7000 Troubleshooting And Maintenance Manual page 91

Hide thumbs Also See for Storwize V7000:
Table of Contents

Advertisement

v Quorum drive identifiers in the format: <enclosure_serial>:<drive slot
ID>[<drive 11S serial number>] (7 characters, colon, 1 or 2 numbers,
open square bracket, 22 characters, close square bracket), for example,
01234A9:21[11S1234567890123456789]
v Quorum MDisk identifier in the format: WWPN/LUN (16 hexadecimal
digits followed by a forward slash and a decimal number), for example,
1234567890123456/12
- If the error data contains a node identifier, ensure that the node that is
referred to by the ID is showing node error 578. If the node is showing a
node error 550, ensure that the two nodes can communicate with each
other. Verify the SAN connectivity, and if the 550 error is still present,
restart one of the two nodes from the service assistant by clicking Restart
Node.
- If the error data contains a quorum drive identifier, locate the enclosure
with the reported serial number. Verify that the enclosure is powered on
and that the drive in the reported slot is powered on and functioning. If the
node canister that is reporting the fault is in the I/O group of the listed
enclosure, ensure that it has SAS connectivity to the listed enclosure. If the
node canister that is reporting the fault is in a different I/O group from the
listed enclosure, ensure that the listed enclosure has SAS connectivity to
both node canisters in the control enclosure in its I/O group. After
verification, restart the node by clicking Restart Node from the service
assistant.
- If the error data contains a quorum MDisk identifier, verify the SAN
connectivity between this node and that WWPN. Check the storage
controller to ensure that the LUN referred to is online. After verification, if
the 550 error is still present, restart the node from the service assistant by
clicking Restart Node.
- If there is no error data, the error is because there are insufficient
connections between nodes over the Fibre Channel network. Each node
must have at least two independent Fibre Channel logical connections, or
logins, to every node that is not in the same enclosure. An independent
connection is one where both physical ports are different. In this case, there
is a connection between the nodes, but there is not a redundant connection.
If there is no error data, wait 3 minutes for the SAN to initialize. Next,
verify:
v There are at least two Fibre Channel ports that are operational and
connected on every node.
v The SAN zoning allows every port to connect to every port on every
other node
v All redundant SANs (if used) are operational.
After verification, if the 550 error is still present, restart the node from the
service assistant by clicking Restart Node.
Note: If after resolving all these scenarios, half or greater than half of the
nodes are reporting node error 578, it is appropriate to run the recovery
procedure. Call the IBM Support Center for further assistance.
– For any nodes that are reporting a node error 550, ensure that all the missing
hardware that is identified by these errors is powered on and connected
without faults. If you cannot contact the service assistant from any node,
isolate the problems by using the LED indicators.
– If you have not been able to restart the system, and if any node other than
the current node is reporting node error 550 or 578, you must remove system
Chapter 7. Recovery procedures
73