Table 28. Error event IDs and error codes (continued)
Event
Notification
ID
type
Condition
029002
E
The system failed to create a bad block because MDisk
already has the maximum number of allowed bad
blocks.
029003
E
The system failed to create a bad block because the
clustered system already has the maximum number of
allowed bad blocks.
030000
W
The trigger prepare command has failed because of a
cache flush failure.
030010
W
The mapping is stopped because of the error that is
indicated in the data.
030020
W
The mapping is stopped because of a clustered system or
complete I/O group failure, and the current state of the
relationship could not be recovered.
045001
E
One or more power supply unit fans have failed.
045002
E
A fan is operating outside the expected range.
045003
E
There was a fan status communications failure.
045004
E
The power supply unit is not installed.
045005
W
The power supply unit has indicated an input power
failure.
045006
E
The power supply unity has indicated an output failure.
045007
E
The power supply unit has failed.
045008
E
There is no communication with the power supply unit.
045009
E
The model type for this enclosure is not valid.
045010
E
The power supply unit type is unknown to this product.
045011
E
The power supply unit serial number is not valid.
045012
W
The canister temperature is at the warning level.
045013
W
The canister temperature is at the critical level.
045014
E
The SAS cable was excluded because of a missing device. 1260
045015
E
A SAS cable was excluded because too many change
events were caused.
045016
E
A SAS cable was excluded.
045017
E
A SAS cable is operating at a reduced speed.
045018
E
A SAS cable was excluded because frames were dropped. 1260
045019
E
A SAS cable was excluded because the enclosure
discovery timed out.
045020
W
A SAS cable is not present.
045021
E
A canister was removed from the system.
045022
E
A canister has been in a degraded state for too long and
cannot be recovered.
045023
E
A canister is encountering communication problems.
045024
E
The canister VPD is not valid.
045025
E
The canister has experienced too many resets.
045026
E
The drive slot is causing the network to be unstable.
Error
code
1226
1225
1900
1910
1895
1124
1126
1126
1128
1138
1126
1124
1148
1124
1124
1124
1098
1095
1260
1255
1260
1260
1265
1036
1034
1038
1032
1032
1686
Chapter 9. Event reporting
133

Advertisement

Table of Contents
loading

Table of Contents