THE FORCE/1
Maintenance, Cont.
Gearbox/Agitator/Airlock Unjamming procedure:
disconnect all electrical cords to machine. Tip machine upside down onto
hopper, locate and remove fan cover on agitator motor. Note: Depending
upon the motor used it will be necessary to remove the screws holding
the fan cover on before removal, otherwise all other covers may be pried
off using screwdriver. By hand, carefully turn fan blade in the direction of
the arrow as indicated on label until jam is cleared. Note: It will take
approximately 15 turns of the fan blade before you start to reverse the
entire airlock system. Caution! Fan blade may break if excessive force
is used.
Note: The gearbox and the airlock must be perpendicular to each other.
Proper alignment prevents premature wear on the gearbox and airlock
shaft connection.