Generators And Extension Cords - Intec Force 1 Instruction Manual

Table of Contents

Advertisement

THE FORCE/1

Generators and Extension Cords

Your FORCE/1 will operate on power from a commercial-sized
generator. No household generators may be used due to the high
inrush requirements of the FORCE/1. Also, generators made by
Honda, Yamaha, Coleman and Generac are not recommended.
While they are of high quality, these generators do not have the inrush
protection devices necessary to start the FORCE/1 and protect the
generator. The start-up requirement for a FORCE/1 is 3450 watts;
normal operating requirement is 1725 watts. We recommend a
generator of not less than 4000 watts, 115 VAC. In addition, Intec
recommends generators that have a 50% power boost feature which
aids the generator in high current startups.
Running additional equipment from the same generator means you will
need to know the total electrical requirements before selecting the
correct size of generator. For details on selecting and purchasing a
generator, please call INTEC.
Note: Using a generator of insufficient size will void your Warranty.
Adding Additional Power Cords.
Cord Current Capacities, Type S & SVT
Wire
Size
AWG
The length of cord and ambient temperature does have an effect on the
electrical current capacity. Consult Intec for your specific needs or your
local electrical distributor.
3
Conductor
Amps
10
25
12
20
14
15
16
10
18
7
20
4
Conductor
Amps
20
15
12
8
6

Hide quick links: