4. FLOW PRIORITY VALVE
The flow priority valve is a flow divider that divides the
flow from single hydraulic source (hydraulic pump) to
actuates two circuits simultaneously.
This valve feeds fixedly controlled flow (7 L/min., 1.8
U.S.gals./min., 1.5 Imp.gals./min.) to the PF port with
priority and excessive flow to the EF port.
(1) Spring
(2) Spool
(3) Valve Body
5-M4
HYDRAULIC SYSTEM
EF : EF Port (to 3 point hitch
control circuit)
PF : PF Port (to power steering
PTO clutch and HST
circuit)
P : Pump Port