OTHER FUNCTIONS

TEMPORARY BYPASSING OF THE WEEKCLOCK
In the weekclock mode the temperature setting value can temporary be changed manually with the arrow
buttons. The change is valid until the beginning of the following period after which the weekclock will
continue according to the earlier determined program.
BUTTON LOCK
The buttons can be locked and unlocked by pushing the both arrow buttons simultaneously for a long
time. When the buttons are locked the symbol of the button lock is displayed.
FAULT SIGNALS
If the room temperature sensor is faulty the code"E1" is displayed.
If the floor temperature sensor is faulty the code"E2" is displayed.
THE EMERGENCY OPERATION TIME
If the power is switched off for less than 2 hours all the settings will remain. If the power cut lasts longer
than 2 hours the clock will reset. After the power is switched on the right time must be entered so that the
thermostat is able to follow the timed settings.
SETTINGS
MOVING IN THE SETTING MENU
The thermostat settings can be changed in the setting menu. The thermostat can be changed from the
basic mode into the setting mode by pushing the OK button for a longer time and return to the basic mode
by pushing the OK button once again for a longer time.
Moving from one menu to another is done by pushing the arrow buttons and the desired menu is chosen
by pushing the OK button. In the setting mode the symbol of the chosen menu is displayed.
The thermostat will return into the basic mode 60 seconds after a button has been pushed. In this case the
unconfirmed choices will not be saved.
SETTING THE DAY OF WEEK AND CLOCK
The day of week and clock are entered in the
Enter the day of week by pushing the arrow buttons and confirm the setting by pushing the OK button
(1=Monday, 2=Tuesday, 3=Wednesday etc)
Enter the time by pushing the arrow buttons and confirm the setting by pushing the OK button.
SETTING THE WEEKCLOCK
The weekclock settings are entered in the
Enter the starting time for the period 1C with 15 minutes accuracy by pushing the arrow buttons and
confirm the setting by pushing the OK button.
Enter the desired temperature value for the period 1C with 0.5°C accuracy by pushing the arrow
buttons and confirm the setting by pushing the OK button.
Repeat the instructions above to enter the starting times and temperatures for the periods 2E...6E.
NOTE! The weekclock sets the desired values for a certain period of time. While using the weekclock it
should be taken into consideration that it may take several hours to warm up the floor construction into
the desired temperature. That is why the temperature rising and dropping times should be predicted when
setting the weekclock periods.
SETTING THE EXTERNAL TEMPERATURE CHANGE
The temperature value of the external temperature change is entered in the
14
menu.
menu.
menu.