Malfunction
Expansion tank is defective.
Water quantity or water pressure in the sys-
tem is too high.
Safety pressure relief
valve is leaking or always
open.
Safety pressure relief valve is stuck.
Tab. 4-1 Possible malfunctions of the HPSU compact
4.3 Fault codes
Code
Error message
Display Internal
9001
80
Fault DHW sensor
9002
81
Fault frost protec-
9003
89
tion function.
9004
7H
Fault flow rate
Flow temperature
9005
8F
> 75 °C
Flow temperature
9006
8H
> 65 °C
IG main board
9007
A1
defective
Refrigerant tem-
9008
A5
perature
9009
AA
STB fault
9010
AC
9011
C0
Fault flow sensor
FA ROTEX RoCon HP - 03/2013
Possible cause
Component/Designation
Temperature sensor feed
water temperature
Temperature sensor dis-
charge water temperature
Failure of the frost protec-
tion function of the water
heat exchanger
Flow disruption water cir-
cuit
Outlet water temperature
in HPSU compact > 75 °C
Outlet water temperature
in HPSU compact > 65 °C
PCB A1P HPSU compact Malfunction message. Contact ROTEX heating technician.
Optional: STB backup
heater (BOH)
Bridge on board A1P
FlowSensor
4
x
Faults and malfunctions
Possible solution
Replace expansion tank.
On the controller (rotary switch setting "Info"
check whether there is adequate water pressure
(> 0.3 bar) (must be below the stated maximum
pressure) and drain water off until it lies mid-range.
Check safety pressure relief valve and if necessary,
replace it.
– Turn the red knob on the safety pressure relief
valve counterclockwise. If you can hear a rattling
noise, the safety pressure relief valve needs
replacing.
– Close the inlet and discharge stop valve if water is
continuously escaping.
Fault and possible causes
Flow temperature sensors t
Return temperature sensors t
Failure of the frost protection function of the water heat exchanger
because the water flow is too low. See fault code "7H".
Failure of the frost protection function of the water heat exchanger
because there is a lack of refrigerant in the system.
Water flow is too low or there is none at all, minimum water flow
required ( 12 l/min). Check the following items:
All stop valves of the water circuit must be completely open.
Optional water filters must not be contaminated.
System must run within its operating parameters.
System must be completely evacuated.
On the controller (rotary switch setting "Info"
whether there is adequate water pressure (> 0.3 bar).
The external static pressure must correspond to the character-
istic curve in the technical data for the heat generator.
A higher pressure indicates internal resistance in the water
circuit.
Expansion tank is defective.
If this fault occurs during defrost operation in the operating
mode room heating or hot water supply: With optional backup
heater: check its power supply and fuses.
In the switch cabinets of HPSU compact, check the pump
fuse (FU1) and circuit board fuse (F1).
Discharge water temperature in HPSU compact is too high
(> 65 °C).
– Temperature sensor discharge water temperature pro-
vides incorrect values.
– With installed backup heater: STB in backup heater (BUH)
has triggered.
STB in backup heater (BUH) has triggered.
Check and unlock position of STL.
Bridge of connection socket "X21A" missing on the board A1P.
Flow sensor on HPSU compact is defective.
and t
are defective.
V1
V2
and t
are defective.
R1
R2
) check
)
31