GB
5.3
Symbols and Control panels
Arc 180
Arc 200
5.4
Overheating protection
The welding power source has a thermal overload trip which operates if the
temperature becomes too high, interrupting the welding current and lighting a yellow
indicating lamp on the front of the power source. The thermal overload trip resets
automatically when the temperature has fallen.
5.5
MMA welding
Move process selector switch to desired welding process.
NOTE: Power source output is enabled.
Check welding cable polarity selection matches electrode requirements. Select
desired welding current level.
5.5.1
Welding current setting
The Arc 180 power source has an adjustable welding current from 5
to 180 Amps.
The Arc 200 has an adjustable value from 5 to 200 Amps.
bh40d1e
Power ON
Indicating lamp, white,
power supply ON
Scratch TIG
- 9 -
Overheating
Indicating lamp, yellow,
overheating
MMA welding
© ESAB AB2011