Figure 7. Configuration Tool (Option Config.)

ⓡ Inactivity time
After the connection is established, if there is not data transmission within the time defined
in Inactivity time, the connection is closed automatically.
The default value is '0'. If '0' is set, this function is not activated. In this default setting, the
connection is maintained even though there is no data transmission. In order to close the
connection, the 'Close' command should be given.
This function can be used for more than two or more systems to connect to a WIZ110SR
module. If one system keeps connection to the WIZ110SR, other systems can not connect to
the module. If there is no data transmission during the time defined in Inactivity time, the
connection will be closed for other system to be connected.
Inactivity Time also can be useful for the case when the server system is unexpectedly shut
down. In this status, if there is not any data communication during the time defined in the
Inactivity time, WIZ110SR will close the connection and enter into waiting status.