ⓢ Data Packing Condition
You can designate how the serial data can be packed to be sent to the Ethernet. There are 3
delimiters - time, size and character. If all of them are set as '0', whenever the serial data is
arrived, they are sent to the Ethernet.
a. Time: Every designated time, serial data converted to Ethernet.
b. Size: Every designated data size, serial data converted to Ethernet.
c. Char: Every designated character, serial data converted to Ethernet. (It's available only
Hex.)
When any of three delimiters is satisfied, data can be sent to the Ethernet.
Ex) Delimiter: Size=10, Char=0x0D
Serial data : 0123456789abc
Ethernet data : 0123456789
"abc" data remains in the serial buffer of module
☞
Copyright © WIZnet All Rights Reserved