Drive States - IBM System x3850 X5 Implementation Manual

Redbooks
Hide thumbs Also See for System x3850 X5:
Table of Contents

Advertisement

To install the MSM software, read the Installation and User's Guide for MSM at the following
website.
http://ibm.com/support/entry/portal/docdisplay?lndocid=SERV-RAID
You must have administrator or root equivalent operating system privileges to install and fully
access the MegaRAID Storage software.
There are four setup options:
Complete: This option installs all program features.
Client: This option installs the required components to remotely view and configure
servers.
Server: This option only installs the required components for remote server management.
Stand Alone: This option only installs the required components for local server
management.

9.13.2 Drive states

A
drive group
There are multiple drive states. The following list describes all of the possible drive states:
Online
A drive that can be accessed by the RAID controller and is part of the virtual drive.
Unconfigured Good
A drive that is functioning normally but is not configured.
Hot Spare
A drive that is powered up and ready for use as a spare in case an online drive fails. There
are two Hot Spare drive states: Dedicated and Global.
Failed
A drive that was originally configured as Online or Hot Spare, but on which the firmware
detects an unrecoverable error.
Rebuild
A drive to which data is being written to restore full redundancy for a virtual drive.
Unconfigured Bad
A drive on which the firmware detects an unrecoverable error.
Missing
A drive that was Online but which has been removed from its location.
Offline
A drive that is part of a virtual drive but which has invalid data as far as the RAID
configuration is concerned.
522
IBM eX5 Implementation Guide
is one or more drives that are controlled by the RAID controller.