IBM System x3850 X5 Implementation Manual page 517

Redbooks
Hide thumbs Also See for System x3850 X5:
Table of Contents

Advertisement

64 bit
32 bit
Figure 9-47 Files installed in the ASU folder
4. Run a command, such as the asu show command, either in-band or out-of-band, using the
commands that are listed in Table 9-4. This command confirms that the connection and
utility work.
Table 9-4 Steps to run ASU both in-band and out-of-band
In-band
1. Run the following command:
- For 32 bit: asu show
- For 64 bit: asu64 show
Example 9-1 shows the output from running the asu show command in-band.
Example 9-1 Output from the asu show command in-band
IBM Advanced Settings Utility version 3.61.70I
Licensed Materials - Property of IBM
(C) Copyright IBM Corp. 2007-2010 All Rights Reserved
Successfully discovered the IMM via SLP.
Discovered IMM at IP address 169.254.95.118
Connected to IMM at IP address 169.254.95.118
IMM.SSH_SERVER_KEY=Installed
Out-of-band
1. Ping the IMM to ensure that you have a network
connection to the IMM. The default IP address is
192.168.70.125. Note: You might need to change
your IP address.
2. Run the following command:
- For 32 bit: asu show --host IPADRESS
- For 64 bit: asu64 show --host IPADRESS
Chapter 9. Management