Target Workloads; Ibm Bladecenter Hx5 - IBM System x3850 X5 Implementation Manual

Redbooks
Hide thumbs Also See for System x3850 X5:
Table of Contents

Advertisement

Feature
HS22
DIMMs per
Two
channel
DIMM sockets
12
Maximum
96 GB
installable RAM
(8 GB DIMMs)
Memory type
DDR3 ECC VLP
RDIMMs
Internal disk
2x Hot-swap 2.5"
drives
drive
SAS, SATA, or SSD
I/O expansion
One CIOv
One CFFh
serial-attached
Onboard LSI 1064
SCSI (SAS)
Optional ServeRAID
controller
MR10ie (CIOv)
Embedded
Internal USB socket
Hypervisor
for VMware ESXi
Onboard
Broadcom 5709S
Ethernet
Chassis
BladeCenter E (certain restrictions)
supported
BladeCenter H
BladeCenter S
BladeCenter HT

5.2 Target workloads

The HX5 is designed for business-critical workloads, such as database and virtualization.
Virtualization provides many benefits, including improved physical resource utilization,
improved hardware efficiency, and reduced power and cooling expenses. Server
consolidation helps reduce the cost of overall server management and the number of assets
that have to be tracked by a company or department.
Virtualization and server consolidation can provide the following benefits:
Reduce the rate of physical server proliferation
Simplify infrastructure
Improve manageability
Lower the total cost of IT, including power and cooling costs
The HX5 2-socket and HX5 4-socket are strong database systems. They are ideal upgrade
candidates for database workloads that are already on a blade. The multicore processors,
large memory capacity, and I/O options make the HX5 proficient at taking on database
workloads that are being transferred to the blade form factor.
HS22V
HX5
Three
One
18
30 mm: 16
60 mm: 32
144 GB
30 mm: 128 GB
60 mm: 256 GB
DDR3 ECC and
DDR3 ECC VLP
non-ECC VLP
RDIMMs
RDIMMs
2x Non-hot-swap 1.8"
Two or four
SSD
non-hot-swap 1.8"
SSDs (require the
SSD Expansion Card)
One CIOv
Per 30mm blade:
One CFFh
Onboard LSI 1064
LSI 1064 controller on
Optional ServeRAID
the optional SSD
MR10ie (CIOv)
Expansion Card
Internal USB socket
Internal USB socket
for VMware ESXi
for VMware ESXi
Broadcom 5709S
Broadcom 5709S
HX5 with MAX5
HX5: One
MAX5: Two
40
320 GB
DDR3 ECC VLP
RDIMMs
Two non-hot-swap 1.8"
SSDs (require the SSD
Expansion Card)
Per 60mm blade:
One CIOv
One CIOv
One CFFh
One CFFh
LSI 1064 controller on
the optional SSD
Expansion Card
Internal USB socket for
VMware ESXi
Broadcom 5709S
BladeCenter H
BladeCenter S
BladeCenter HT (ac model only)
Chapter 5. IBM BladeCenter HX5
181

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bladecenter hx5System x3690 x5System x3950 x5

Table of Contents