Enabling Sol In Uefi - IBM System x3850 X5 Implementation Manual

Redbooks
Hide thumbs Also See for System x3850 X5:
Table of Contents

Advertisement

In this section, we describe these topics:
9.14.1, "Enabling SoL in UEFI" on page 526
9.14.2, "BladeCenter requirements" on page 527
9.14.3, "Enabling SoL in the operating system" on page 529
9.14.4, "How to start a SoL connection" on page 533

9.14.1 Enabling SoL in UEFI

To enable SoL from the UEFI interface at boot time, press F1 when given the option and
select System Settings  Devices and I/O Ports  Console Redirection Settings. In
Table 9-7, you can find the UEFI settings that need to be set.
Table 9-7 Settings in UEFI for SoL
Value
General settings
COM Port 1
COM Port 2
Remote Console
Serial Port Sharing
Serial Port Access Mode
SP Redirection
Legacy Option ROM Display
COM settings
Baud Rate
Data Bits
Parity
Stop Bits
Terminal Emulation
Active After Boot
Flow Control
Settings in UEFI for SoL:
COM Port 1 has to be enabled only if the HX5 is used within a BC-H or BC-S where the
Serial Pass-thru Module is implemented.
Terminal Emulation can be set either to VT100 or ANSI; however, when configuring
Linux operating systems, make sure that the OS settings match the terminal emulation
that is selected in the hardware.
526
IBM eX5 Implementation Guide
HX5
Disable
Enable
Enable
Not available
Not available
Not available
COM Port 2
115200
8
None
1
VT100
Enable
Hardware
x3850 X5 and x3690 X5
Enable
Enable
Enable
Enable
Shared
Enable
COM Port 2
115200
8
None
1
VT100
Enable
Hardware

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bladecenter hx5System x3690 x5System x3950 x5

Table of Contents