Tapping Method
1. Turn on the power switch on the rear of the unit. Allow unit to cycle through its start up program.
Select stick on the selector switch.
2. Make sure electrode holder is connected to the positive connector and the work clamp is connect-
ed to the negative connector. If welding with E6010 or a electrode (rod) with a cellulose based flux,
connect the work clamp to the 6010 port.
3. Select the amps desired. Use the electrode diameter selection chart below to determine the ap-
proximate range of amps suitable for the rod size selected. Consult the welding electrode manufac-
turer's recommendation for proper amperage range. Each manufacturer has specific recommenda-
tions for its electrodes regarding amp range, though a general range can be determined.
4. Strike the arc with either the tapping method or the match strike method. Beginners usually find
that the match strike method yields best results. Professionals tend to gravitate toward the tapping
METAL THICKNESS
< 1 mm/.040"
2 mm/.080"
3 mm/ 1/8"
4-5 mm/ 3/16"
6-12 mm/ 1/4"-1/2"
>12mm/>1/2"
STICK OPERATION TECHNIQUE
STARTING METHODS
DC STICK (SMAW) OPERATION GUIDE
ELECTRODE SIZE
1.5 mm/ 1/16"
2 mm/3/32"
3.2 mm/1/8"
3.2-4 mm/ 1/8"-3/16"
4–5 mm/ 3/16"
>5mm/3/16"
18
GENERAL SETUP AND OPERATION
Scratch/Match Method
WELDING AMPS
20-40
40-90
80-150
100-170
130-250
200-300