Section 2
GENERAL SETUP AND OPERATION
PowerARC 300ST
STANDARD WELDING CONFIGURATION
6010
WORK (-)
NOTE: Use this configuration with most standard electrodes except ones with cellulose flux such as E6010/6011.
TORCH (+)
IMPORTANT: Most electrodes require DCEP (+). Always consult electrode manufacturer directions before using DCEN (-).
16