Wiring - Everlast POWERARC 300ST Operator's Manual

Analog dc stick/dc tig igbt inverter welder
Table of Contents

Advertisement

Section 2
1~220 V
GAS
OR
INLET
3~220v
3 PHASE WIRE COLORS FOR POWERARC 300
GREEN: GROUND
RED:L3
WHITE: L2
BLACK: L1
PLUG IS NOT INCLUDED! IT MUST BE SUPPLIED BY CUSTOMER.RECOMMENDED
PLUG IS A NEMA 6-50P FOR SINGLE PHASE USE. CONSULT A LICENSED ELEC-
TRICIAN AND LOCAL CODES BEFORE MODIFYING EXISTING CIRCUITS OR IN-
STALLING THE WELDER. See page 20 for further details and explanation.
HF
EVERLAST IS NOT RESPONSIBLE FOR DAMAGE OR INJURY RESULTING FROM IMPROPERLY WIRED WELDERS!
Fe, Cu
PowerARC 300ST

Wiring

1 PHASE 220/240 V SHOWN. FOR 3-PHASE 220/240 VUSE, CONSULT LICENSED ELECTRICIAN
L2,WHITE; HOT (240V 1or 3 phase)
Even though the unit is grounded by the main ground wire to the chassis,
an additional bonded ground may be necessary in some locations to
comply with code. Consult a locally licensed electrician concerning the
any requirement of this connection and its proper use and application.
GENERAL SETUP AND OPERATION
GREEN GROUND (220/240V 1 and 3 phase)
NEMA 6-50P
FULLY TAPE RED WIRE SO THAT IS IS OUT OF THE WAY AND COVERED FOR
SINGLE PHASE USE! RED WIRE IS FOR 3 PHASE 220/240 V USE ONLY!
IMPORTANT:
14
L1,BLACK; HOT(240V 1 or 3 phase)
L3,RED; HOT(240V 3 phase only)