Error Messages
Error Messages
Error Messages
Must have at least 1 edge specified. You must assign at least one
clock edge to one of the available clocks in the Master clocking
arrangment. In addition, if the Slave clock is being used, it must have at
least one clock edge assigned. The analyzer
will
not let you close the
clock assignment pop-up until an edge is specified.
Time correlation of data is not possible. Before time correlation of
data is possible, time tags must be placed on the data.
If
you want time
correlated data, set the Count field in the Trigger menu to Time.
Maximum of 32 channels per label. This message appears when you
try to assign more than 32 channels to a
~ingle
label. The logic analyzer
will
only allow 32 channels to be assigned to any single label.
NO DISK. There are no disks in the disk drives. You must place a disk
into the disk drive before configurations can be loaded or stored.
Timer is off in sequence level. At least one sequence level has
specified a timer as part of the sequence instruction and that timer is not
turned on. The timer must be set to either Start, Pause, or Continue.
Timer is specified in sequence, but never started. A timer is
specified somewhere
in
the sequence, but was not started. The timer
must be set to Start. The timer can be set to Start in any sequence level.
Problems reading file. The user is trying to translate a configuration
file that can not be opened a second time.
Inverse assembler not loaded - bad object code. Corrupt inverse
assemble file.
Try
getting another copy of the inverse assembler file and
loading that.
Insufficient memory to load IAL - load aborted. There is not a
block of free memory large enough to load inverse assembler.
ASCII entry not available. The ASCII base is not available. You must
use another base selection.
No Room for Selected Macro. The macro selected required more
physical sequence levels than are available. Reconfigure sequence levels
or use a different macro.
11-3