Operation

Activating/deactivating magnetic clamp

Switching machine ON/OFF

MAB 485
Activating magnetic clamp
CAUTION
Switch on the magnetic clamp only when the machine is
standing on a magnetic substrate to avoid overheating of the
magnet.
Turn on switch (22). The indicator light in switch (22) comes
on.
Check the magnet clamping force at the magnet indica-
tor (24). When the magnet clamping force is sufficient, the
MAGNET POWER indicator light (24) is green. If the MAG-
NET POWER indicator light (24) is red, there is not sufficient
magnet clamping force available.
CAUTION
The maximum magnet clamping force is only available after
switching on the motor.
Deactivating magnetic clamp
Secure the machine at the handle to prevent the machine
from slipping off the surface.
Turn off switch (22). The indicator light in switch (22) goes
out.
Turn the machine ON at the ON/OFF switch (21) with the
green button (I) and OFF with the red button (O).
NOTE
The machine can only be switched on when the magnetic
clamp has been switched on.
Allow a severely overheated machine to run on at no-load
speed for approx. 2 minutes to let it cool down.
The machine switches off automatically in the event of a
power failure or if the magnetic clamp is switched off.