Download Print this page

Maintenance - Beko ÖWAMAT 6 Instructions For Installation And Operation Manual

Oil water separator

Advertisement

Maintenance • Mantenimiento
(1)
(2)
Oil outlet
Salida de aceite
Sortie d'huile
Saída de óleo
22
Entretien • Manutenção
english

Maintenance

• Shut off condensate inlet (if neces-
sary switch off compressor).
• Where there is a heating system,
disconnect the device from the
power supply!
Cleaning of dirt collector (1)
(recommended every 6 months)
• Keep a basin at hand for catching the
dirt.
• Detach the feed hose from the pres-
sure relief chamber.
• Undo the screws.
• Lift the pressure relief chamber
upwards.
• Pull out the the dirt collector slow-
ly, catch the dirt, and ensure cor-
rect disposal .
• Put back the dirt collector, fix the
pressure relief chamber and recon-
nect the feed line.
Checking of oil outlet (2)
(recommended every 6 months)
Open the lid:
• Is there a free oil passage? If not
Ü clean the oil outlet.
• Is the oil being discharged from the
present layer of oil? If not
Ü move the adjustment ring down-
wards by a few mm.
Close the lid.
General cleaning of ÖWAMAT
(recommended every 12 months)
- Clean dirt collector.
- Empty the separation container by
pumping.
- Clean separation container.
- Ensure correct disposal of the li-
quid.
Note:
Do n ot add any cleaning agents
(su rfactan ts)! They impair the
filter efficiency.
After cleaning, fill the ÖWAMAT unit
with fresh water.
After maintenance work
• Open condensate inlet.
• If there is a heating system, recon-
nect the power supply.
ÖWAMAT 6, 8

Advertisement

loading

This manual is also suitable for:

Öwamat 8