Program Example When Gx Configurator-Ct Is Used - Mitsubishi Electric QD62 User Manual

Q series high-speed counter module
Hide thumbs Also See for QD62:
Table of Contents

Advertisement

8 PROGRAMMING

8.2.1 Program example when GX Configurator-CT is used

Device
W0 to W1
W 2 to W 3
W 4 to W 5
W 6 to W 7
W8 to W 9
W 10
W 20 to W 35
X20
X21
X22
X23
X24
X25
X26
X27
X28
X29
X2A
X2B
X2C
X2D
Y30
Y31
X1020
X1022
Y1020
Y1021
Y1022
Y1024
Y1026
T1 to T5
8 - 12
(1) List of devices
Device that current value flag is written by auto refresh
Device that latch count value flag is written by auto refresh
Device that sampling count value is written by auto refresh
Device that periodic pulse count previous value is written by auto refresh
Device that periodic pulse count present value is written by auto refresh
Overflow status storage
Interrupt enabled flag storage for the IMASK instruction
Count operation start signal
Current value read signal
Coincidence output data setting signal
Preset command signal
Count operation stop signal
Coincidence LED clear signal
Counter function execution start signal
Counter function execution stop signal
Latch count data read signal
Latch execution signal
Sampling count data read signal
Sampling count start signal
Periodic pulse count data read signal
Periodic pulse count start signal
Coincidence confirmation LED signal
Overflow occurrence confirmation LED signal
Module ready
Counter value coincidence (point No. 1)
Coincidence signal No. 1 reset command
Preset command
Coincidence signal enable command
Count enable command
Counter function selection start command
Interlock for own station and other stations
Function
QX10 (X20 to X2F)
QY10 (Y30 to Y3F)
QD62 (X/Y1020 to X/Y102F)
MELSEC-Q
8 - 12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qd62eQd62d

Table of Contents