Hide thumbs

Advertisement

4 SETUP AND PROCEDURE BEFORE STARTING THE OPERATION
Item
0
Switch 1
(for channel 1)
Switch 2
(for channel 2)
Switch 3
Switch 4
Switch 5
4 - 17
2) Click the Switch setting button. Consequently, the Switch
setting for the "I/O and intelligent function module" dialog
box will be displayed.
Data item
Pulse input mode
0: 1-phase multiple of 1
H
1: 1-phase multiple of 2
2: CW/CCW
3: 2-phase multiple of 1
4: 2-phase multiple of 2
5: 2-phase multiple of 4
Counting speed setting
0: 10 k PPS
1: 100 k PPS
2: 200 k PPS
3: 500 k PPS
Counter format
0: Linear counter
1: Ring counter
Same data item as the switch 1 (for CH1).
No settings (blank)
When any item is set, delete the settings and leave the field blank.
POINT
The counting speed setting of 500kPPS can only be used with the QD62D. Setting
the counting speed to 500k PPS for the QD62 and QD62E may cause miscounts.
Thus, do not use this setting for the QD62 and QD62E.
The reserved switches in the intelligent function module switch setting items are for
system use, not for users. Therefore, always fix them to 0. If used (changed from 0
to 1) by a user, the operations of the QD62(E/D) are not ensured.
3) After the setting, click the End button.
Sets the pulse input mode.
Sets the counting speed.
(Only for the QD62D)
Sets the counter format.
MELSEC-Q
Select "HEX".
Description
Reference
Section 5.1.1
Section 3.1
Section 5.1.1
Section 5.1.2
-
-
4 - 17