Chapter 4 - Commissioning The Supply Section With Isu; Overview; Installation Checklist - ABB ACS 600 User Manual

Aca 635 igbt supply sections (isu) 260 to 4728 kva
Hide thumbs Also See for ACS 600:
Table of Contents

Advertisement

Chapter 4 – Commissioning the Supply Section with ISU

Overview

Installation Checklist

Check that the mechanical and electrical installation of the
frequency converter is inspected and OK.
Ensure that the insulation resistance of the assembly is
checked according to instructions given in the Hardware
Manual.
Ensure that the surroundings and inside of the cabinet is
free from dust and loose objects (like cable trimmings and
other waste left from the installation).
ACA 635 IBGT Supply Sections
This chapter describes the commissioning of a supply section that is
equipped with the IGBT Supply Unit (ISU).
WARNING! Only qualified electricians are allowed to commission the
drive. The Safety Instructions on the first pages of this manual must be
followed. Ignoring the safety instructions can cause injury or death.
The installation must be checked before commissioning the supply
section. This table refers to the more detailed instruction.
Action
Information
See ACS 600 MultiDrive Hardware
Manual (EN code: 63700118) or ACx
6x7 Hardware Manual (EN
code:61329005). Refer to Installation
Checklist and Insulation Checks
(Chapter 3).
After the start, the cooling air fans may
suck nearby loose objects into the unit.
This might cause failure and damage the
unit.
4-1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents