  • Page 1 ACS600, ACS800 Installation Guide du/dt Filters AOCH0260-70 AOCH0400-70 NOCH0016-6x NOCH0030-6x NOCH0070-6x NOCH0120-6x NOCH0260-60 NOCH0400-60 NOCH0760-60...
  • Page 2 3AFE 58933368 REV D EFFECTIVE: 20.10.2003  2003 ABB Oy. All Rights Reserved.
  • Page 3: Table Of Contents

    Table of contents Table of contents du/dt Filters Installation Guide Contents ..............5 General notes and restrictions .
  • Page 4 Table of contents...
  • Page 5: Du/Dt Filters Installation Guide

    du/dt Filters Installation Guide Contents This document contains the following information: • General notes and restrictions • Technical data (including allowable ambient conditions) • Internal circuit diagrams • Power connection diagrams • Filter selection tables • Dimensional drawings (including terminal sizes and tightening torques). General notes and restrictions Observe the following before you start to install the du/dt filters: WARNING! Do not attempt any work on a powered drive.
  • Page 6 • Maximum motor cable length for NOCH0xxx-6x filters (cumulative for several parallel-connected motors): NOCH0016-60/62 150 m NOCH0030-60/62 (can be increased to 300 m by NOCH0070-60/62 connecting two filters in series) NOCH0120-62 NOCH0016-65 50 m NOCH0030-65 (can be increased to 100 m by NOCH0070-65 connecting two filters in series) NOCH0120-65...
  • Page 7: Technical Data

    • NOCH0xxx-6x filters are designed to cool by natural convection, thus the following free space requirements apply: Wall-mounted filter units: 300 mm on each free side. Exception: 500 mm above the filter if installed below the drive. Floor-mounted filter units: 300 mm on each free side.
  • Page 8: Ambient Conditions, Transportation

    Ambient conditions, storage Ambient storage conditions refer to the conditions du/dt filters are subjected to during storage in the protective package. ° Temperature: -40 to +70 Relative humidity: Less than 95%, no condensation allowed Atmospheric pressure: 70 to 106 kPa Vibration: AOCH0xxx-70: Max 1 mm (5 to 13.2 Hz), max 7 m/s (13.2 to 100 Hz) sinusoidal...
  • Page 9: Internal Circuit Diagrams

    Internal circuit diagrams input 1 (A) 2 (X) output AOCH0xxx-70: Connect the input terminals together. 1 (A) 1 (A) 2 (X) 2 (X) NOCH0260-60 NOCH0120-60 NOCH0400-60 NOCH0760-60 U1 V1 W1 V2 W2 NOCH0016-6x NOCH0120-6x NOCH0030-6x NOCH0070-6x du/dt Filters Installation Guide...
  • Page 10: Power Connections

    Power connections NOCH0400-60 NOCH0260-60 NOCH0400-60 NOCH0760-60 du/dt Filters Installation Guide...
  • Page 11 NOCH0016-6x NOCH0120-6x NOCH0030-6x NOCH0260-60 NOCH0070-6x NOCH0400-60 NOCH0760-60 AOCH0260-70 AOCH0400-70 du/dt Filters Installation Guide...
  • Page 12 NOCH0760-60 du/dt Filters Installation Guide...
  • Page 13 NOCH0400-60 du/dt Filters Installation Guide...
  • Page 14 NOCH0400-60 du/dt Filters Installation Guide...
  • Page 15 AOCH0400-70 AOCH0260-70 du/dt Filters Installation Guide...
  • Page 16 NOCH0120-6x: Cable lug installation [16 to 70 mm (6 to 2/0 AWG) cables] Isolate the ends of the cable lugs with insulating tape or shrink tubing. NOCH0120-6x: Cable terminal installation [95 to 185 mm (3/0 AWG to 350 MCM) cables] a.
  • Page 17: Filter Selection Tables

    Filter selection tables du/dt filter type (* 3 filters included in kits marked with *) IP 00, x=2 IP22, x=5 IP 54 SingleDrive 400 V 500 V 690 V 60x- 0005-3, 0006-3 0006-5, 0009-5 0009-6, 0011-6 0009-3, 0011-3 0011-6, 0016-6 0016-6 0016-3, 0020-3 0020-5, 0025-5 0020-6, 0025-6 0030-6...
  • Page 18 du/dt filter type (3 filters included in kits marked with *) MultiDrive IP 00, x=2 IP22, x=5 IP 54 400 V 500 V 690 V 6xx- 0005-3, 0006-3 0006-5, 0009-5 0009-6, 0011-6 0009-3, 0011-3 0011-6, 0016-6 0016-6 0016-3, 0020-3 0020-5, 0025-5 0020-6, 0025-6 0030-6 0025-3, 0030-3 0030-5, 0040-5...
  • Page 19: Dimensional Drawings

    Dimensional drawings du/dt Filters Installation Guide...
  • Page 20 du/dt Filters Installation Guide...
  • Page 21 du/dt Filters Installation Guide...
  • Page 22 du/dt Filters Installation Guide...
  • Page 23 du/dt Filters Installation Guide...
  • Page 24 NOCH0760-60 Weight: 43 kg (95 lbs) du/dt Filters Installation Guide...
  • Page 25 du/dt Filters Installation Guide...
  • Page 26 64787845-A du/dt Filters Installation Guide...
  • Page 28 ABB Oy ABB Inc. AC Drives Automation Technologies P.O. Box 184 Drives & Motors FIN-00381 HELSINKI 16250 West Glendale Drive FINLAND New Berlin, WI 53151 Telephone +358 10 22 11 +358 10 22 22681 Telephone 262 785-3200 Internet http://www.abb.com 800-HELP-365...