48

Enable Manual Spa Heat Control

If this option is selected, your spa will begin to heat whenever it is manually turned on, (by pressing the Spa button
on the ScreenLogic main screen), even if the heater is set to OFF. Your spa will also begin to heat when turned on
by the spa-side remote, or QT4 wireless remote. This feature allows you to program your spa to filter daily with the
heater set to off, and then be ready to heat whenever the SPA button is pressed manually on the ScreenLogic Main
screen. This feature is switched on by default.
To set manual heat control for the spa:
1. Start the ScreenLogic Configurator and tap Configure IntelliTouch.
2. Tap Next on the General Setting page and on the Setup Circuits page. The Configure Other Equipment
(Step 3 of 5) page is displayed.
3. Tap the Spa Manual Heat check box.
4. Tap Finish when done.

Chlorine Generator

The IntelliTouch system is designed to operate with the following salt chlorine generators:
AutoPilot Pool Pilot Digital
GoldLine Aqua Rite
Clear Tech Automation AutoClear Plus
Note: Call your manufacturer for compatibility with IntelliTouch systems.

Activate the Chlorinator Control Interface

Before operating the chlorinator control interface you must first activate the system to control the chlorinator from
the ScreenLogic. ScreenLogic can control the chlorinator but does not turn the chlorination system on or off. When
the chlorinator control is disabled in ScreenLogic, the chlorinator is still operating but must be controlled at the
chlorinator control panel.
To obtain chlorination status and make adjustments:
1. Start the ScreenLogic Configurator and tap Configure IntelliTouch.
2. Tap Next on the General Setting page and on the Setup Circuits page. The Configure Other Equipment
(Step 3 of 5) page is displayed.
3. Tap the Chlorinator present check box to enable chlorination.
4. Tap Finish.
Note: For information about Chlorinator user controls, refer to "Equipment Tab," page 76.