Changing the Display to Show Fahrenheit to Celsius

Temperature set point and actual temperature settings are displayed on the Main screen in either Fahrenheit or
Celsius.
To change the temperature scale:
1. Start the ScreenLogic Configurator utility, and tap Configure IntelliTouch.
2. On the General Setting page under Temperature Scale, tap either Fahrenheit or Celsius.
3. Tap Finish when done to save the setting.

Calibrating Temperature Sensors

The IntelliTouch system includes two temperature sensors (10 kohm) for water and ambient air temperature. The
IntelliTouch i10+3D model for dual bodies of water has three sensors. You can add an additional sensor for
controlling solar heating systems.
Generally, these sensors are accurate and you do not have to calibrate them. However, long plumbing runs and
water features can cause temperatures at a body of water to be different from the temperature sensor reading. You
can manually recalibrate the sensors to adjust for this.
Before you start, you need an accurate all weather thermometer. If you are calibrating the air sensor, wait until the
sensor is not in direct sunlight.
There is a Water Temp and Air Temp setting. If you have an i10+3D system, you will see Spa Temp, Pool Temp,
and Air Temp. Calibrate the Spa and Pool temperatures the same way as described below for Water Temp. For
the i5, i5S, i7+3, or i9+3 system, there is a water and air temperature sensor. Make sure to locate the air
temperature sensor in the shade for accurate readings.
To calibrate the air, pool and spa sensors:
1. First, tap the Pool or Spa button on the ScreenLogic Main screen to switch on the spa or pool filter pump.
2. Tap Configure IntelliTouch to start the ScreenLogic Configurator.
3. Place the thermometer in the spa or pool. Take an accurate temperature reading. When calibrating the air
sensor, place the thermometer next to the air sensor. The sensor is normally located near or under the Load
Center or Power Center enclosure, not inside the enclosure. Take an accurate temperature reading in the
shade.
4. On the General Setting page under Calibrate Sensors, use the Up or Down arrows to raise or lower the Air,
Pool and Spa temperature to match the corresponding thermometer temperature reading. If you have an
i10+3D repeat the above for the pool. The i10+3D has three sensors, one each for the spa and pool water
and one for the air temperature.
5. Press Finish when done.
IntelliTouch ScreenLogic User's Guide