Takenaka System FS5000GE Instruction Manual page 26

Gige vision compliant 5 megapixel progressive scan color camera
Table of Contents

Advertisement

(7-4) How to set Gain
"G" command is used for gain setting.
Transmission from host: STX : "G" : MGC set value : AGC set value : (VRT set value) : VRB set value : OFFSET set value : ETX
Return by camera:
MGC gain setting ... Setting the fixed gain.
[Example] To set the MGC gain to "123"(=H'7B)
Transmit as follows
Transmission from host: STX: "G": "7B" : "...." ETX
(Note) "...." (four periods)
Right figure shows the example of transmitting the command using
FCTool. The MGC set value is set to "7B".
AGC gain setting ... Setting the AGC gain (reference value).
[Example] To set the AGC gain to "82"(=H'52)
Transmit as follows
Transmission from host: STX: "G" : " ." : "52" : " ... " ETX
[Explanation] The replacement of set value by " . "
It can use " . " as replacement of the parameter value which should not be changed, if it is needed to change only the specific
parameters by the communication command accompanying plural parameters such as "G" command.
For example, in the case of AGC gain setting four " . " are used as replacement of each of "MGC","VRB","VRT" and "OFFSET".
Gain setting in AEC.... In AEC (Auto Exposure Control), AGC gain set value is applied as the reference value and MGC set
CC D
S/H
MGC set value
When AEC function is ON, the value displayed at the left side of GAIN
column on OSD menu is MGC set value, and the value displayed at the right
side is AGC set value.
( → MGC set value=75, AGC set value=70 in the right example)
In the AEC function, the shutter exposure time is automatically controlled
with reference to AGC set value( comparative level).
The average of image output level is increased or decreased in proportion to
AGC set value.
Increase the AGC set value when it is needed to increase the output image luminance.
Preamplifier gain of A/D converter is defined in terms of MGC gain value.
MGC gain value can be set independently of AGC set value.
If MGC set value is increased, the sensitivity is improved but the S/N ratio degrades.
[Example] To set AGC set value (reference value) to "75" (=H'4B) and MGC set value(preamplifier gain) to "100" (=H'64) .
Transmit as follows
Transmission from host: STX: "G": "64" : "4B" : "..." ETX
STX : ACK : ETX (transaction completion) or STX : NAK : ETX (transaction rejection)
value as the fixed preamplifier gain value.
Preamplifier
A /D
GAIN
AGC set value
Shutter exposure time control
Block diagra m of AEC control
Im age output
to GiG E I/F
Log ical comparison
COMP
- 26 -
M10510B;26/58
*M ENU
M ENU
:
ON
G AIN
:
75
/
70 AEC
OFFSET:
140
S.TIM E:A 484 h
(
14.31)m s
S.FORM: NORM AL
/
AEC ON
Menu1 display

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fc2200geFs2200ge

Table of Contents