………………………………………………… 16 7. Serial communication control ………………………………………………… 25 8. Timing chart ………………………………………………… 29 9. Notes ……………………………………………… 35 10. Specifications ………………………………………………… 36 11. Dimensions ………………………………………………… 37 TAKENAKA SYSTEM CO., LTD. Document No. N11A27 FS2300DV Instruction Manual (3 Version) - 1 -...
Page 2
Document Version Revised contents Articles Date Remarks version Initial version 2010-07-16 N10601 FS2300DV version Error correction 2011-06-21 N11311A version Error correction 2011-10-27 N11A27 Description of special remarks used in this manual (Note) ················ Particulars which require the user’s attention are explained.
N11A27;3/37 1. Features FS2300DV is a full frame shutter color camera incorporated with 2.01 megapixel, 1/1.8”-size CCD image sensor. ● A full frame shutter image can be obtained at a rate of 20 frames per second. ● The RGB 8 bit digital image signal output complying with Camera Link (Base Configuration).
N11A27;4/37 3. Description of Each Component Camera Link connector (3-1) Description of rear panel of camera Panel to set up operation mode, electronic shutter speed and C am e r a L i nk Operation indicator(LED) other parameters and to connect each output connector D V I (3-2) Camera connector (HRS HR10A-7R-6PB) POWER...
Page 5
N11A27;5/37 [Table of Camera Link bit assignment] (showing correspondence relation between before and after encoding) Camera Link port Camera signal Remark (Node name) name Strobe Pixel clock LVAL Horizontal synchronous timing FVAL Vertical synchronous timing DVAL (Fixed to H level) Spare (Fixed to H level) Red/Green/Blue Lowermost data...
N11A27;6/37 (3-4) DVI-D output,HDMI connector Pin No. DVI signal name Pin No. DVI signal name D V I TMDS DATA 2+ TMDS DATA CLK shield TMDS DATA 2 shield TMDS DATA CLK- TMDS DATA 2- TMDS DATA 1+ External view of HDM I connector TMDS DATA 1 shield DDC/SCL (Viewed from the outside of the cam era)
Page 7
N11A27;7/37 [Important] (Note) Make sure to turn off the power switch of the camera before connecting or disconnecting the camera cable. If the cable is connected or disconnected while the power is supplied, it may cause the camera troubles. (Note) Make sure to turn off the camera and connected devices in advance before connecting the camera.
Page 8
N11A27;8/37 ● Recommended timing of asynchronous shutter trigger signal (Vinit signal) for preset shutter/pulse width control For the case of preset shutter mode, the negative logic pulse is Tvinit applied within the width range from 1 H (one horizontal Vinit synchronous time) to 1ms as described below.
Page 9
N11A27;9/37 (4-3) Other input/output circuit +3.3V From internal circuit ● Strobe signal output circuit Strobe signal: Pin ** of The internal output circuit is shown in the camera connector right figure. 6.8N 74VHCT04A (!) The strobe signal of this camera is 3.3V (or equivalent) logic level.
Page 10
N11A27;10/37 (4-6) Monitoring function for internal temperature of camera This camera is equipped with an internal temperature sensor to monitor the temperature inside the camera housing. This function makes it possible to use the camera in a safer way even in a harsh environment in terms of temperature, for example use in the open air.
Page 11
N11A27;11/37 (Example 2) Where Td, the returned value of the temperature data, is “H’03FA” in the hexadecimal system, it is expressed in the binary system as follows: Td=H’03F1=B’0000.0011.1111.1010 ∴ Db=B’11.1111.1010 (Only upper 10 digits of Td are valid.) → Dt=-6 (↓ Refer to [Explanation]) Then, Tc is calculated from the following formula: Tc=Dt×0.5°...
N11A27;12/37 5. Various Settings Electroni c shutter (5-1) Operation mode operation mode Shutter swi tch = 0 Shutter switch = 1 to 9 ● CCD output … Single out No shutter Elec troni c shutter (1 port output) operation operation ●...
Page 13
N11A27;13/37 ・The operation mode of the camera can be changed by changing the argument data of the serial communication command “H’21,H’22”. Communication command H’21 Enabled STRB signal output H reset Selection of CC1 polarity 0 : OFF 0 : OFF 0 : Positive polarity used used...
Page 14
N11A27;14/37 (5-3) Level setting The level setting is mostly divided into the Si gn al le ve l following two groups: 1 0 2 3 ● Gain setting I mag e si gna l (B efo re s et tin g ad ju stm en t ) This is to set the gain (amplification ratio) of the preamplifier between the CCD 0...
Page 15
N11A27;15/37 (5-5) Data save and data read setting This camera incorporate nonvolatile memories and various operation mode settings and level settings can be stored on them. And the data set at each address is overwritten with the contents of nonvolatile memories at the time of power-on.
N11A27;16/37 6. How to Change Setting (6-1) How to set hypothetical shutter switch The shutter speed is determined mainly by the setting positions of the hypothetical shutter switch from “0” to “9”. It can be set by changing the argument data of the communication command “H’32”. Table 6-1 Setting value of shutter speed Shutter speed Position of...
Page 17
N11A27;17/37 ● Menu display It can switch the menu displayed by OSD function. Refer to section 6-6 for more information about the displayed menu. The OSD menu can be switched by entering the argument [H’00 H’04] to the communication command “H’20”. ●...
Page 18
N11A27;18/37 ● RED digital gain It can change the RED digital gain when outputting Camera Link signal and RGB 8bit signal for the monitor. Variable range is approximately 0.01 to 4-fold when assuming 0x40 as reference 1-fold in a fixed-point system. Also, the sampling value (the average value of 15 points when M E N U 2 Gain is invalid) of each RGB output is displayed on OSD.
Page 19
N11A27;19/37 ● Serial communication baud rate The serial communication baud rate of this camera is fixed to 9600 bps. ● Test pattern It outputs the color bar signal from the camera as the Camera link output and monitor output. Refer to the section (4-5) “Test pattern display function” for more details. ●...
Page 20
N11A27;20/37 Table 6-5 [OSD menu 4] setting Communication Argument data Set contents command Default Setting range H’01 to H’04 H’45 Operating cursor (CURSOR) H’01 H’ Horizontal data Start / Width (X_DATA SX/W) H’0018 to H’064C ✳✳ H’ H’0007 to H’04C4 Vertical data Start / Width (Y_DATA SY/W) ✳✳...
Page 21
N11A27;21/37 ● Setting of cursor 1(White) display/hide, shape setting It can set the shape of cursor 1. It can be changed by entering the argument [H’00 to H’03] to the communication command “H’40” as follows. H’00 : Hide cursor H’01 : Lattice-shaped cursor H’02 : Box-shaped cursor H’03 : Cross-shaped cursor Box-shaped...
Page 22
N11A27;22/37 ● Hide setting of the cursor (Camera Link output) It can hide the cursor for Camera Link output separately from the cursor for monitor output.. ● Cursor movement It can move each cursor by entering an argument to the communication command H’48 as follows after setting the operating cursor number by the communication command H’49.
Page 23
N11A27;23/37 (6-6) Description of menu display by OSD (On Screen Display) This camera is equipped with the OSD function of superimposing a character information on the output digital image signal. Using this function, the current setting status of the camera can be displayed over OSD display area the image of the capture board in menu-driven form.
Page 24
N11A27;24/37 S.TIME: The current shutter speed is displayed. The left number is H number (horizontal synchronous time unit / in the case of high speed shutter – range: 1 to 1023) or V number (vertical synchronous time unit / in the case of low speed shutter –...
N11A27;25/37 7. Serial Communication Control FS2300DV can be externally controlled via the Camera Link serial interface . (Note) When the operation modes of the camera are changed by the communication functions, it takes some time to switch the modes. Carefully note that normal image may not be obtained from the signal of each one frame before and after transmitting a command.
Page 26
N11A27;26/37 ・Do not send the character string to the camera that is not described in the instruction manual. It may cause a malfunction. Command Byte Functions Default Setting range (Low 8bit) H’00 Prohibited to use - - H’01 Camera version info. -...
Page 27
N11A27;27/37 Command Byte Functions Default Setting range (Low 8bit ) Cursor movement 01 : 02 : 03 : 04 : H’48 ↑ ↓ ← → - H’49 Operating cursor No. I to 4 H’01 H’00 ~ H’04 H’4A Moving amount of cursor 00: 1 01: ±...
Page 28
N11A27;28/37 control (Low Byte Functions Default Setting range 8bit ) H’D2 Operation mode status (High speed shutter /Low speed shutter) - - H’D3 Operation mode status (Pulse width control ON/OFF) - - H’D4 Operation mode status (Strobe signal ON /OFF) -...
N11A27;29/37 Timing Chart ● Pixel clock timing (common in various operation modes) Ca me ra L in k [Phase relationship between clock output and data] DEMULTIPLEX. Co nn ec to r 1 PCLK=20.8ns 10bit A/D PC LK 12/10/8bit Cl o ck ou tp u t 10 ns (max) Di g it a l da t a (LDV ,FDV )
Page 30
N11A27;30/37 Color codi ng (Hor izontal out put tim ing) (Odd line) R G R G R G R G R CCD output signal 16 2 8 E f fe c ti ve pi x el s (Even line) G B G B G B G B CCD...
Page 31
N11A27;31/37 ● Vertical timing: High speed/Pulse width control/Asynchronous shutter/Without H-reset n Vi ni t HD ( Inte rnal hor izon tal sync sig nal) E n d o f e x p o su r e ( S e n s o r g a t e ) 2 47×...
Page 32
N11A27;32/37 ● Vertical timing: High speed/Preset shutter/Asynchronous shutter/With H-reset Vinit 1~2 ×PCLK HD (Internal horizontal sync signal ) n End of e xposur e (Sen so r g ate) 247×PCLK Expo sure time (nH) 1250×P CLK n+2 1250 Camera Link FVAL...
Page 33
N11A27;33/37 ● Vertical timing: High speed/Pulse width control/Asynchronous shutter/With H-reset m×PCLK Vinit 1~2 ×PCLK 1~2 ×PCLK HD (Internal horizontal sync signal) En d of expos ure (Sen so r ga te) 247×PCLK E xpos ure time 125 0×P CLK 1 250 Camera Link FVAL...
Page 34
N11A27;34/37 ● Vertical timing: Low speed (Long exposure)/Preset shutter/Continuous shutter Long exposure timing 1V = 1252 VD ( I n t e r n a l v e r t i c a l s y n c s i g n a l ) Ex p o su r e t im e (...
N11A27;35/37 9. Notes [General notes] ● This equipment is not allowed to be used for medical purposes, detection of hazardous materials or any other operations of which performance may exert influence on human lives or safety. ● We assume no responsibility whatsoever for any incidental damages (loss of business interests, business interruption, change in data, loss of data etc.) resulting from the user’s use of this equipment or performance failure.
N11A27;36/37 [Countermeasures against heat] [Important] The equipment is subject to temperature increase caused by internal power consumption as its overall size is notably small. Place the equipment on the high thermal conductive mount to fix it. Consider to use a cooling system such as separately sold heat sink (HS500) or air-cooled fan, if the increase of temperature is a concern.