[Example] To set shutter switch to "2"
Transmit as follows
Transmission from host: STX: "WSSW": "2": ETX
Right figure shows the example of transmitting the command using
the TAKENAKA's communication software for evaluation (FCTool)
(Note) STX(=H'02) and ETX(=H'03) are automatically inserted before and after
the input character string in the case of using FCTool.
Command "RSSW"
Function: Command for reading out the shutter switch set value (Read Shutter Switch)
Transmission from host: STX : "RSSW" : ETX
Return by camera:
The current "set value" (one character: "0" to "9") of the shutter switch is read out.
[Example] To read out the current set value of shutter switch
Transmit as follows
Transmission from host: STX: "RSSW": ETX
Right figure shows the example of transmitting the command using
FCTool. Set value of shutter switch "2" is read out.
Command "SSSW"
Function: Command for saving the shutter switch set value (Save Shutter Switch)
Transmission from host: STX : "SSSW" : ETX
Return by camera:
The current "set value" (one character: "0" to "9") of the shutter switch is saved into nonvolatile ROM.
(Note) The current set value of the shutter switch can be confirmed on OSD menu
screen. In the right example, it shows that the current shutter switch position is "2".
[External designation of shutter switch position]
It can set the shutter speed by the external designation command for the shutter
switch setting to the one that corresponds to the set value (0 to 9) of the shutter speed
regardless of the current shutter switch position (displayed as "SS= " in OSD menu).
This set value can be saved separately into the program page (A to F).
Command "S"
Function: Command for setting the shutter mode and the shutter exposure time (Shutter)
Transmission from host: STX : "S" :
Return by camera:
The current shutter mode and shutter exposure time are set.
Specified parameter or " . "(period=no change) is entered into
(Note) Refer to "8.Serial communication command" for the detail about command provisions.
[Example] To change the current shutter switch setting to "3" by external designation.
Transmit as follows
Transmission from host: STX : "S...S3.." : ETX
Right figure shows the example of transmitting the command using
FCTool. The shutter switch set value is changed to "3" as designated exposure
time.
[External designation of shutter exposure time]
It can externally designate the shutter exposure time (horizontal scan time: in H unit) by " S " command in the same fashion.
It is done by assigning 4-digit values (in hexadecimal system) to "exposure time " in the above transmission data.
[Example] To set the current shutter exposure time to hundredfold of the horizontal scan time ("0064" in hexadecimal system)
Transmit as follows
Transmission from host: STX : "S...0064" : ETX
(Note) Settable minimum value of the shutter exposure time is "0001" (=D'1), the maximum value is "0819" (=D'2073) in high
speed shutter mode and "H'00FF" (=D'255) in low speed shutter mode.
The normal image cannot be output if the value beyond the above range is set.
Also, the external shutter setting is cancelled when "0000" (=D'0) is designated. (next section)
STX : ACK : set value : ETX (transaction completion), or STX: NAK : ETX (transaction rejection)
STX : ACK : set value : ETX (transaction completion), or STX : NAK : ETX (transaction rejection)
1 :
2 :
3 : exposure time : ETX
STX : ACK : set value : ETX (transaction completion), or STX : NAK : ETX (transaction rejection)
1 to
3 part.